Rosemount™ 928 Wireless Gas Monitor

$0.00
sold out

The Rosemount 928 Wireless Gas Monitor detects hydrogen sulfide (H2S), carbon monoxide (CO), and oxygen depletion (O2) in remote applications previously too challenging and costly to monitor. This wireless toxic gas monitoring system enhances worker safety through early gas leak detection, simply integrates with WirelessHART® technology, and eliminates the need for expensive wiring. The Rosemount 928 Wireless Gas Monitor easily connects to the Rosemount 628 Universal Gas Sensor which consists of a tool-less-hot-swappable smart sensor module.

Add To Cart

The Rosemount 928 Wireless Gas Monitor detects hydrogen sulfide (H2S), carbon monoxide (CO), and oxygen depletion (O2) in remote applications previously too challenging and costly to monitor. This wireless toxic gas monitoring system enhances worker safety through early gas leak detection, simply integrates with WirelessHART® technology, and eliminates the need for expensive wiring. The Rosemount 928 Wireless Gas Monitor easily connects to the Rosemount 628 Universal Gas Sensor which consists of a tool-less-hot-swappable smart sensor module.

The Rosemount 928 Wireless Gas Monitor detects hydrogen sulfide (H2S), carbon monoxide (CO), and oxygen depletion (O2) in remote applications previously too challenging and costly to monitor. This wireless toxic gas monitoring system enhances worker safety through early gas leak detection, simply integrates with WirelessHART® technology, and eliminates the need for expensive wiring. The Rosemount 928 Wireless Gas Monitor easily connects to the Rosemount 628 Universal Gas Sensor which consists of a tool-less-hot-swappable smart sensor module.


FEATURES

Hot-swappable electrochemical sensor module with end-of-life diagnostics that can be installed in the field without tools.

Replaceable, intrinsically safe lithium-thionyl chloride power module. The power module has over two years of service life and can be easily exchanged in the field in hazardous locations.

WirelessHART technology is secure, cost-effective and delivers >99% data reliability

Easy, intuitive installation enables a quick method to add safety monitoring without the cost of wiring

High performance monitoring comparable to conventional wired gas monitors with an accuracy of ±3 ppm or 10% of reading, whichever is greater

 

SPECIFICATIONS

Operating Temperature: H2S: -40 °F to +122 °F (-40 °C to +50 °C)
O2 Depletion: -22 °F to +122 °F (-30 °C to +50 °C)
CO: -22 °F to +122 °F (-30 °C to +50 °C)

Update Rate: 1 second to 60 minutes, user selectable

Time Constant / Response:

H2S:

  • T20 < 8 seconds

  • T50 < 10 seconds

  • T90 < 45 seconds

O2:

  • T90 < 15 seconds

Detection Range: H2S: Gas Concentration Level 0-100 ppm range
O2 Depletion: Gas Concentration Level 0-25 % by volume
CO: Gas Concentration Level 0-1,000 ppm range

Power Supply: Replaceable, intrinsically safe lithium-thionyl chloride power module with PBT polymer enclosure

Antenna Type: PBT/PC integrated omnidirectional antenna

Humidity Range: H2: 10-95 % Relative Humidity Non Condensing
O2: 10-95 % Relative Humidity Non Condensing
CO: 5-95 % Relative Humidity Non Condensing

Enclosure Rating: IP66 ingress protection (IP) filter

Housing Material: Low-copper aluminum (A360) or stainless steel

Certifications/Approvals: Intrinsically Safe, CSA Division 1, and ATEX/IECEx Zone 0

Outputs: IEC 62591 WirelessHART 2.4GHz DSSS. Optional discrete output to support local alarms

Accuracy: H2S: ± 3 ppm or 10 % of reading, whichever is greater
O2 Depletion: ±Within 0.5 % of oxygen content of supply gas
CO: ± 6 ppm or 10 % of reading, whichever is greater